Products

Let the world use good meters

ES4000 Power Quality Analyzer

Please enable JavaScript in your browser to complete this form.

Power supply

Rechargeable lithium-ion battery packs 9.6V, backup charger.

Battery indicator

Battery symbol       shows dump energy. When the voltage is too low, automatic shutdown after the 1 minute.

Power consumption

Current consumption of normal test 490 mA, continuous working for 10 hours.

Display mode

LCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm.

Size of clamp

FR008 small sharp current clamp: 8mm×15mm;

FR020 circle current clamp: 20mm×20mm;

FR050 circle current clamp: 50mm×50mm.

FR300R Flexible Coil Current Sensor (with Integrator) : Ф300mm

Instrument dimensions

L×W×H: 277.2mm × 227.5mm × 153mm.

Number of channels

4U/4I.

Phase-to phase voltage

1.0V~2000V.

Phase-to-neutral voltage

1.0V~1000V.

Current

FR008 current clamp: 10mA~10.0A;

FR020 current clamp: 0.10A~100A;

FR050 current clamp: 1.0A~1000A;

FR300R Flexible Coil Current Sensor (with Integrator) : 10A ~ 6000A

Phase-to-neutral voltage

1.0V~1000V.

Parameters of electricity

W, VA, Var, PF, DPF, cosφ, tanφ.

Energy parameters

Wh, Varh, Vah.

Harmonic

Order 0~50.

Total harmonic distortion

Order 0~50, each phase.

Expert mode

Yes.

Number of Transient records

150 sets.

Voltage flicker

Yes.

Starting current mode

Yes, 100 seconds.

3 phases unbalance

Yes.

Record

300 days(simultaneous recording 20 parameters, record one point every 5 seconds).

Min/Max recorded value

Measurement of maximum and minimum values over a period of time.

Alarm

40 different types of parameter selections, 12,800 sets alarm logs.

Peak

Yes.

Phasor diagram display

Automatically.

Capacity of snapshots

60.

Menu language

English/Chinese.

Communication

USB.

Automatic switching off

When an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off.

 

In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute.

Backlight function

Yes, suitable for use at night and dark place.

Weight

Host: 1.6kg (with battery).

 

FR008 small sharp current clamp: 168g×4;

 

FR020 circle current clamp: 252g×4;

 

FR050 circle current clamp: 463g×4;

 

FR300R Flexible Coil Current Sensor (with Integrator) : 280g×4;

 

Test wires and power adapter: 800g;

 

Total weight: about 10.8kg (with packaging).

Length of voltage test wire

3m.

Length of current sensor wire

2m.

Working temperature and humidity

-10°C~40°C; below 80%Rh.

Storage temperature and humidity

-10°C~60°C; below 70%Rh.

Input impedance

Input impedance of test voltage: 1MΩ.

Withstand voltage

Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell.

Insulation

Between instrument wiring and shell ≥10MΩ.

Structure

Double insulation, with insulation vibration-proof sheath.

Safely rules

IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.

Scroll to Top

Get prices and catalogue

Ultra low price

Fill out the form below, and we will be in touch shortly.

Please enable JavaScript in your browser to complete this form.